X
(847) 734-1600

KKT chillers, Inc. Chiller Training Syllabus

Day 2 - Introduction to Second Generation KKT Chillers, ECO Series

Basic configurations of the different water circuit models including the Siemens Medical Equipment Terminology of the different modalities.

  1. ECO 122L - Aera
  2. ECO 133L - Skyra

General Information Regarding:

  1. Transfer Station
    1. General Description
    2. Types of Transfer Stations
      1. IFP 098
      2. IFP 090
    3. Water Circuit Overview
      1. IFP 098
      2. IFP 090
  2. Installation
    1. Ambient Temperature
    2. Clearance
    3. Water Connections
    4. Glycol
    5. Piping
    6. Air Vents
    7. Voltages, Frequency and Tolerances
    8. Piping Overview
      1. ECO 122L
      2. ECO 133L
  3. Startup
    1. Prior Commencement
    2. Checking Power Supply
    3. Filling the Unit
    4. Running the Pump
    5. Final Verification Checklist
      1. Power Checks
      2. Pressure Checks
  4. Preventative Maintenance
    1. Overview
    2. Weekly Checks
    3. Annual Recommended Parts Replacements
    4. Task Overview
      1. Control Cabinet
      2. Pipe and Expansion Tank
      3. Electric Control panel
      4. Chiller Compressor
      5. Condenser and Fan
      6. Heat Exchanger
      7. Chiller Water System
      8. Chiller Water Pump
  5. Chiller Components
    1. Compressor
    2. Condenser
    3. Filter Drier
    4. Sight Glass
    5. Expansion Valve
    6. Evaporator
    7. Pump
    8. Filter Ball Valve
  6. Function, Controls and Modes
    1. Day Mode
      1. ECO 122L
      2. ECO 133L
    2. Night Mode
      1. ECO 122L
      2. ECO 133L
    3. Compressor
    4. Fan
    5. Expansion valve
    6. Pump
  7. Troubleshooting
    1. Failure Analysis of the CPU

Day 3 - Introduction to Second Generation KKT Chillers, MedixX Series

Basic configurations of the different water circuit models including the Siemens Medical.

  1. MedixX 50 - SEP Chiller for Symphony / Harmony Quantum and Aera (XJ - gradient)
  2. MedixX 60 - SEP Chiller for Avanto, Espree, TaTs, Verio and Aera / Skyra (XQ – gradient)
  3. MedixX 70 - SEP Chiller for Biograph mMR

General Information Regarding:

  1. Transfer Station
    1. General Description
    2. Transfer Stations
      1. TSN (Transfer Station Normal)
      2. SEP Cabinet (Separator)
    3. Water Circuit Overview
      1. TSN (Transfer Station Normal)
      2. SEP Cabinet (Separator)
  2. Installation
    1. Ambient Temperature
    2. Clearance
    3. Water Connections
    4. Glycol
    5. Piping
    6. AirVents
    7. Voltages, Frequency and Tolerances
    8. Piping Overview
      1. MedixX 50
      2. MedixX 60
      3. MedixX 70
  3. Startup
    1. Prior Commencement
    2. Checking Power Supply
    3. Filling the Unit
    4. Running the Pump
    5. Final Verification Checklist
      1. Power Checks
      2. Pressure Checks
  4. Preventative Maintenance
    1. Overview
    2. Weekly Checks
    3. Annual Recommended Parts Replacements
    4. Task Overview
      1. Control Cabinet
      2. Pipe and Expansion Tank
      3. Electric Control panel
      4. Chiller Compressor
      5. Condenser and Fan
      6. Heat Exchanger
      7. Chiller Water System
      8. Chiller Water Pump
  5. Chiller Components
    1. Compressor
    2. Condenser
    3. Filter Drier
    4. Sight Glass
    5. Expansion Valve
    6. Evaporator
    7. Pump
      1. Filter Ball Valve
  6. Function, Controls and Modes
    1. Pump
    2. Compressor
    3. Fan
    4. Expansion valve e. Pump
  7. Troubleshooting
    1. Failure analysis of CPU

Day 4 - Introduction of the FCU and Third Generation Training

Basic configurations of the FCU (free cooling unit). Overall function with second generation chillers.

  1. FCU ECO 122L, ECO 133L, MedixX 50, MedixX 60, MedixX 70, cBoxX

General Information Regarding:

  1. Water Circuit Overview
  2. Piping
  3. Installation
  4. Functions
    1. ECOSeries
    2. MedixXSeries
    3. cBoxX series

Hands- on Training:

  1. Troubleshooting
    1. ECO133L
    2. MedixX70
    3. cBoxX
  2. Test